Compressors |
Breathing Air |
| [+]
Portable Compressors |
| [+]
Stationary Compressors |
| [+]
Air Treatment & Testing |
| [+]
Storage |
| [+]
Distribution |
| [+]
Accessories |
|
 |
|
 |
High Pressure
|
High Pressure Air Compressor Units
This section of the homepage will introduce our industrial high pressure compressors for air compression (90 - 500 bar).
High Pressure Air Compressors, I Range 90-350 bar
| Model |
Free air delivery * |
Number of stages |
Speed |
Motor power |
Power consumption |
Net Weight |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
[kW] |
[app. kg] |
| Technical Data VERTICUS Range |
| I 100-3-5 |
85 |
5,1 |
3 |
3 |
900 |
3 |
2,2 |
335 |
| I 100-4-5 |
125 |
7,5 |
4,4 |
3 |
1270 |
4 |
3,3 |
340 |
| I 120-4-5 |
170 |
10,2 |
6 |
3 |
1200 |
4 |
3,7 |
345 |
| I 120-5,5-5 |
215 |
13 |
7,6 |
3 |
1470 |
5,5 |
4,7 |
355 |
| I 12.14-7,5-5 |
300 |
18 |
10,6 |
4 |
1470 |
7,5 |
6,5 |
365 |
| I 15.1-7,5-5 |
340 |
20,4 |
12 |
4 |
1050 |
7,5 |
6,9 |
440 |
| I 15.1-11-5 |
420 |
25,2 |
15 |
4 |
1320 |
11 |
9,6 |
450 |
| I 150-11-5 |
500 |
30 |
18 |
4 |
1230 |
11 |
10,2 |
450 |
| I 180-15-5 |
610 |
36,6 |
21 |
4 |
1320 |
15 |
12 |
470 |
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
| Model |
Free air delivery * |
Number of compressor stages |
Speed |
Motor power |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
| Technical Data I Range (Horizontal version) |
| I 22.0-15 |
650 |
39 |
23 |
4 |
980 |
15 |
| I 22.0-18,5 |
800 |
48 |
28 |
4 |
1180 |
18,5 |
| I 22.0-22 |
930 |
56 |
33 |
4 |
1320 |
22 |
| I 23.0-30 |
1300 |
78 |
46 |
4 |
1200 |
30 |
| I 23.0-37 |
1480 |
89 |
52 |
4 |
1400 |
37 |
| I 25.0-45 |
1900 |
114 |
67 |
4 |
1180 |
45 |
| I 28.0-55 |
2500 |
150 |
88 |
4 |
830 |
55 |
| I 28.0-75 |
3500 |
210 |
125 |
4 |
1180 |
75 |
Standard Scope of Supply
 |
Compressor Unit » Details of the Large Industrial Series (horizontal version) or VERTICUS |
| |
• |
Oil lubrication (high pressure oil pump) |
| |
• |
Micronic intake filter |
| |
• |
Air cooled inter and after coolers for all compressor stages |
| |
• |
Intermediate and final separators for oil and water condensate |
| |
• |
Safety valve after each compressor stage, final pressure safety valve with TÜV approval |
| |
• |
Pressure maintaining valve after last compressor stage |
 |
Automatic condensate drain |
| |
• |
Automatically drains oil and water in the intermediate and final separator while the unit operates |
 |
Electric control unit |
| |
• |
MINI-VERTICUS III: Electronic control; the unit monitors relevant compressor parameters |
| |
• |
VERTICUS and large industrial series: Compressor control (consisting of B-CONTROL and possibly extensions); the unit monitors relevant compressor parameters |
 |
Frame, housing |
| |
• |
MINI-VERTICUS III: Sound absorbing housing ensure quiet running, anti-vibration mounts for foundationless installation |
| |
• |
VERTICUS and large industrial series: Open frame with anti-vibration mounts for foundationless installation |
High Pressure Air Compressors, I Range 350-500 bar
I-Series 350-500 bar
| Model |
Free air delivery * |
Number of stages |
Speed |
Motor power |
Power consumption |
Net Weight |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
[kW] |
[app. kg] |
| Technical Data VERTICUS Range |
| I 15.11-7,5-5 |
310 |
18,6 |
11 |
4 |
960 |
7,5 |
7 |
440 |
| I 15.11-11-5 |
420 |
25,2 |
15 |
4 |
1320 |
11 |
10,4 |
450 |
| I18.1-15-5 |
550 |
33 |
19,5 |
5 |
1320 |
15 |
12,4 |
470 |
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psi
| Model |
Free air delivery * |
Number of compressor stages |
Speed |
Motor power |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
| Technical Data I Range (Horizontal version) |
| I 25.9-45 |
1900 |
114 |
67 |
5 |
1180 |
45 |
| I 25.18-55 |
2300 |
138 |
81 |
5 |
1100 |
55 |
Standard Scope of Supply
 |
Compressor Unit » Details of the Large Industrial Series (horizontal version) or VERTICUS |
| |
• |
Oil lubrication (high pressure oil pump) |
| |
• |
Micronic intake filter |
| |
• |
Air cooled inter and after coolers for all compressor stages |
| |
• |
Intermediate and final separators for oil and water condensate |
| |
• |
Safety valve after each compressor stage, final pressure safety valve with TÜV approval |
| |
• |
Pressure maintaining valve after last compressor stage |
 |
Automatic condensate drain |
| |
• |
Automatically drains oil and water in the intermediate and final separator, while the unit operates |
 |
Electric control unit |
| |
• |
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters |
 |
Frame, housing |
| |
• |
Open frame with anti-vibration mounts for foundationless installation |
|
| |
|