Products
Untitled Document
Home Products Compressors Bauer Industrial Air & Gas Gas Application

Gas Applications

Our Quality - Your System's Reliability

BAUER KOMPRESSOREN builds high pressure systems that employ leading-edge technology and satisfy top-of-the range expectations in design and quality. Our longstanding practical experience know-how design, manufacture and installation make us a competent and reliable supplier of your high pressure compressor system, whatever your specific requirements may be. Depending on pressure and required delivery, BAUER supplies three, four or five stage high pressure gas compressors. This section of our homepage will introduce our product range for gas applications, such as noble gases (such as argon or helium), inert gases (nitrogen, for example) and compressed natural gases (CNG) or methane.

Gas Compression

Our Industrial Systems According to Your Requirements!

Depending on pressure and required air delivery, BAUER KOMPRESSOREN supplies three, four or five stage high pressure gas compressors.
This section of our homepage will introduce our product range for gas applications (90 - 500 bar / 1300 - 7000 psig), such as noble gases (such as argon or helium), inert gases (nitrogen, for example) and compressed natural gases (CNG) or methane.



High Pressure Gas Compressors for Noble Gases (Argon, Helium), G Range 90-220 bar


G-Series 90-220 bar

Model F.A.D. * Number of stages Speed Motor power Power consumption Net Weight
[l/min] [m³/h] [cfm] [rpm] [kW] [kW] [app. kg]
Technical Data VERTICUS Range
G 100-3-5 85 5,1 3 3 900 3 2 535
G 120-4-5 130 7,8 4,6 3 900 4 2,5 540
G 120-5,5-5 175 10,5 6,2 3 1250 5,5 3,6 555
G 15.1-7,5-5 300 18,0 10,6 4 880 7,5 5,5 620
G 15.1-11-5 400 24,0 14 4 1230 11 8,1 650
G 18.1-15-5 560 33,6 20 5 1320 15 11,6 670

* measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig

Model Free air delivery * Number of stages Speed Motor power
[l/min] [m³/h] [cfm] [rpm] [kW]
Technical Data G Range (Horizontal version)
G 22.0-15 610 37 22 4 990 15
G 22.0-18,5 730 44 26 4 1180 18,5
G 23.1-22 810 49 29 4 990 22
G 23.1-30 1030 62 36 4 1250 30
G 25.9-45 1650 100 58 4 1180 45

Standard Scope of Supply


Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
  Oil lubrication (high pressure oil pump)
  Micronic intake filter
  Air-cooled inter and after coolers for all compressor stages
  Intermediate and final separators for oil and water condensate
  Safety valve after each compressor stage, final pressure safety valve with TÜV approval
  Pressure maintaining valve after last compressor stage
Automatic condensate drain
  Automatically drains oil and water in the intermediate and final separator while the unit operates
Electric control unit
  Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
Frame, housing
  Open frame with anti-vibration buffers for foundationless installation



High Pressure Gas Compressors for Noble Gases (Argon, Helium), G Range 220-350 bar

G-Series 220-350 bar


Model F.A.D. * Number of stages Speed Motor power Power consumption Net Weight
[l/min] [m³/h] [cfm] [rpm] [kW] [kW] [app. kg]
Technical Data VERTICUS Range
G 15.1-7,5-5 300 18 10,6 4 880 7,5 5,9 670
G 15.1-11-5 400 24 14 4 1230 11 8,6 670
G 18.1-15-5 550 33 19 5 1320 15 12 670

* measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig

Model Free air delivery * Number of stages Speed Motor power
[l/min] [m³/h] [cfm] [rpm] [kW]
Technical Data G Range (Horizontal version)
G 25.9-45 1650 100 58 4 1180 45

Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
  Oil lubrication (high pressure oil pump)
  Micronic intake filter
  Air-cooled inter and after coolers for all compressor stages
  Intermediate and final separators for oil and water condensate
  Safety valve after each compressor stage, final pressure safety valve with TÜV approval
  Pressure maintaining valve after last compressor stage
Automatic condensate drain
  Automatically drains oil and water in the intermediate and final separator while the unit operates
Electric control unit
  Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
Frame, housing
  Open frame with anti-vibration buffers for foundationless installation



High Pressure Gas Compressors for Inert Gases (Nitrogen), GI Range 90-350 bar

GI-Series 90-350 bar

Model F.A.D. * Number of stages Speed Motor power Power consumption Net Weight
[l/min] [m³/h] [cfm] [rpm] [kW] [kW] [app. kg]
Technical Data MINI-VERTICUS III Range
MV-GI 100-3-3 85 5 3 3 900 3 2,2 265
MV-GI 100-4-3 125 7,5 4,4 3 1270 4 3,1 265
MV-GI 120-4-3 170 10 6 3 1200 4 3,7 270
MV-GI 120-5,5-3 215 13 7,6 3 1470 5,5 4,7 270

measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig

Model F.A.D. * Number of stages Speed Motor power Power consumption Net Weight
[l/min] [m³/h] [cfm] [rpm] [kW] [kW] [app. kg]
Technical Data VERTICUS Range
GI 100-3-5 85 5,1 3 3 900 3 2,2 345
GI 100-4-5 125 7,5 4,4 3 1270 4 3,3 350
GI 120-4-5 170 10,2 6 3 1200 4 3,7 355
GI 120-5,5-5 215 13 7,6 3 1470 5,5 4,7 365
GI 12.14-7,5-5 300 18 10,6 4 1470 7,5 6,5 375
GI 15.1-7,5-5 340 20,4 12 4 1050 7,5 6,9 450
GI 15.1-11-5 420 25,2 15 4 1320 11 9,6 460
GI 150-11-5 500 30 18 4 1230 11 10,2 460
GI 180-15-5 610 36,6 21 4 1320 15 12 480

measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig

Model F.A.D. * Number of stages Speed Motor power Net Weight
[l/min] [rpm] [kW] [app. kg]
Technical Data VERTICUS Range
GIB12.2-5,5-5 6 2 1230 55 3,3
8 4,0
10 4,6
12 5,3
GIB15.3-11-5 8 2 1140 11 6,6
9 7,1
10 7,7
11 8,2

measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig

Model Free air delivery * Number of stages Speed Motor power
[l/min] [m³/h] [cfm] [rpm] [kW]
Technical Data GI Range (Horizontal version)
GI 22.0-15 650 39 23 4 980 15
GI 22.0-18,5 800 48 28 4 1180 18,5
GI 22.0-22 930 56 33 4 1320 22
GI 23.0-30 1300 78 46 4 1200 30
GI 23.0-37 1480 89 52 4 1400 37
GI 25.0-45 1900 114 67 4 1180 45
GI 28.0-55 2500 150 88 4 830 55
GI 28.0-75 3500 210 125 4 1180 75

measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig

Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
  Oil lubrication (high pressure oil pump)
  Micronic intake filter
  Air-cooled inter and after coolers for all compressor stages
  Intermediate and final separators for oil and water condensate
  Safety valve after each compressor stage, final pressure safety valve with TÜV approval
  Pressure maintaining valve after last compressor stage
Automatic condensate drain
  Automatically drains oil and water in the intermediate and final separator while the unit operates
Electric control unit
  Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
Frame, housing
  MINI-VERTICUS III: Sound absorbing housing ensures quiet running, anti-vibration mounts for foundationless installation
  VERTICUS and large industrial series: Open frame with anti-vibration mounts for foundationless installation



High Pressure Gas Compressors for Inert Gases (Nitrogen), GI Range 350-500 bar

GI-Series 350-500 bar

Model F.A.D. * Number of stages Speed Motor power Power consumption Net Weight
[l/min] [m³/h] [cfm] [rpm] [kW] [kW] [app. kg]
Technical Data VERTICUS Range
GI 15.11-7,5-5 310 18,6 11 4 960 7,5 7 440
GI 15.11-11-5 420 25,2 15 4 1320 11 10,4 450
GI 18.1-15-5 550 33,0 19,5 5 1320 15 12,4 480

measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig

Model Free air delivery * Number of stages Speed Motor power
[l/min] [m³/h] [cfm] [rpm] [kW]
Technical Data GI Range (Horizontal version)
GI 25.9-45 1900 114 67 5 1180 45
GI 25.18-55 2300 138 80 5 1100 55

Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
  Oil lubrication (high pressure oil pump)
  Micronic intake filter
  Air-cooled inter and after coolers for all compressor stages
  Intermediate and final separators for oil and water condensate
  Safety valve after each compressor stage, final pressure safety valve with TÜV approval
  Pressure maintaining valve after last compressor stage
Automatic condensate drain
  Automatically drains oil and water in the intermediate and final separator, while the unit operates
Electric control unit
  Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
Frame, housing
  Open frame with anti-vibration mounts for foundationless installation


Copyright © 2007 Allied Solutions Design - ANGLER Technologies