Gas Applications
|
Our Quality - Your System's Reliability
Bauer Kompressoren builds high pressure systems that employ leading-edge technology and satisfy top-of-the range expectations in design and quality. Our longstanding practical experience know-how design, manufacture and installation make us a competent and reliable supplier of your high pressure compressor system, whatever your specific requirements may be. Depending on pressure and required delivery, Bauer supplies three, four or five stage high pressure gas compressors. This section of our homepage will introduce our product range for gas applications, such as noble gases (such as argon or helium), inert gases (nitrogen, for example) and compressed natural gases (CNG) or methane.
Gas Compression
Our Industrial Systems According to Your Requirements!
Depending on pressure and required air delivery, Bauer Kompressoren supplies three, four or five stage high pressure gas compressors.
This section of our homepage will introduce our product range for gas applications (90 - 500 bar / 1300 - 7000 psig), such as noble gases (such as argon or helium), inert gases (nitrogen, for example) and compressed natural gases (CNG) or methane.
High Pressure Gas Compressors for Noble Gases (Argon, Helium), G Range 90-220 bar
G-Series 90-220 bar
| Model |
F.A.D. * |
Number of stages |
Speed |
Motor power |
Power consumption |
Net Weight |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
[kW] |
[app. kg] |
| Technical Data VERTICUS Range |
| G 100-3-5 |
85 |
5,1 |
3 |
3 |
900 |
3 |
2 |
535 |
| G 120-4-5 |
130 |
7,8 |
4,6 |
3 |
900 |
4 |
2,5 |
540 |
| G 120-5,5-5 |
175 |
10,5 |
6,2 |
3 |
1250 |
5,5 |
3,6 |
555 |
| G 15.1-7,5-5 |
300 |
18,0 |
10,6 |
4 |
880 |
7,5 |
5,5 |
620 |
| G 15.1-11-5 |
400 |
24,0 |
14 |
4 |
1230 |
11 |
8,1 |
650 |
| G 18.1-15-5 |
560 |
33,6 |
20 |
5 |
1320 |
15 |
11,6 |
670 |
* measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
| Model |
Free air delivery * |
Number of stages |
Speed |
Motor power |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
| Technical Data G Range (Horizontal version) |
| G 22.0-15 |
610 |
37 |
22 |
4 |
990 |
15 |
| G 22.0-18,5 |
730 |
44 |
26 |
4 |
1180 |
18,5 |
| G 23.1-22 |
810 |
49 |
29 |
4 |
990 |
22 |
| G 23.1-30 |
1030 |
62 |
36 |
4 |
1250 |
30 |
| G 25.9-45 |
1650 |
100 |
58 |
4 |
1180 |
45 |
Standard Scope of Supply
 |
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS |
| |
• |
Oil lubrication (high pressure oil pump) |
| |
• |
Micronic intake filter |
| |
• |
Air-cooled inter and after coolers for all compressor stages |
| |
• |
Intermediate and final separators for oil and water condensate |
| |
• |
Safety valve after each compressor stage, final pressure safety valve with TÜV approval |
| |
• |
Pressure maintaining valve after last compressor stage |
 |
Automatic condensate drain |
| |
• |
Automatically drains oil and water in the intermediate and final separator while the unit operates |
 |
Electric control unit |
| |
• |
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters |
 |
Frame, housing |
| |
• |
Open frame with anti-vibration buffers for foundationless installation |
High Pressure Gas Compressors for Noble Gases (Argon, Helium), G Range 220-350 bar
G-Series 220-350 bar
| Model |
F.A.D. * |
Number of stages |
Speed |
Motor power |
Power consumption |
Net Weight |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
[kW] |
[app. kg] |
| Technical Data VERTICUS Range |
| G 15.1-7,5-5 |
300 |
18 |
10,6 |
4 |
880 |
7,5 |
5,9 |
670 |
| G 15.1-11-5 |
400 |
24 |
14 |
4 |
1230 |
11 |
8,6 |
670 |
| G 18.1-15-5 |
550 |
33 |
19 |
5 |
1320 |
15 |
12 |
670 |
* measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
| Model |
Free air delivery * |
Number of stages |
Speed |
Motor power |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
| Technical Data G Range (Horizontal version) |
| G 25.9-45 |
1650 |
100 |
58 |
4 |
1180 |
45 |
 |
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS |
| |
• |
Oil lubrication (high pressure oil pump) |
| |
• |
Micronic intake filter |
| |
• |
Air-cooled inter and after coolers for all compressor stages |
| |
• |
Intermediate and final separators for oil and water condensate |
| |
• |
Safety valve after each compressor stage, final pressure safety valve with TÜV approval |
| |
• |
Pressure maintaining valve after last compressor stage |
 |
Automatic condensate drain |
| |
• |
Automatically drains oil and water in the intermediate and final separator while the unit operates |
 |
Electric control unit |
| |
• |
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters |
 |
Frame, housing |
| |
• |
Open frame with anti-vibration buffers for foundationless installation |
High Pressure Gas Compressors for Inert Gases (Nitrogen), GI Range 90-350 bar
GI-Series 90-350 bar
| Model |
F.A.D. * |
Number of stages |
Speed |
Motor power |
Power consumption |
Net Weight |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
[kW] |
[app. kg] |
| Technical Data MINI-VERTICUS III Range |
| MV-GI 100-3-3 |
85 |
5 |
3 |
3 |
900 |
3 |
2,2 |
265 |
| MV-GI 100-4-3 |
125 |
7,5 |
4,4 |
3 |
1270 |
4 |
3,1 |
265 |
| MV-GI 120-4-3 |
170 |
10 |
6 |
3 |
1200 |
4 |
3,7 |
270 |
| MV-GI 120-5,5-3 |
215 |
13 |
7,6 |
3 |
1470 |
5,5 |
4,7 |
270 |
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
| Model |
F.A.D. * |
Number of stages |
Speed |
Motor power |
Power consumption |
Net Weight |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
[kW] |
[app. kg] |
| Technical Data VERTICUS Range |
| GI 100-3-5 |
85 |
5,1 |
3 |
3 |
900 |
3 |
2,2 |
345 |
| GI 100-4-5 |
125 |
7,5 |
4,4 |
3 |
1270 |
4 |
3,3 |
350 |
| GI 120-4-5 |
170 |
10,2 |
6 |
3 |
1200 |
4 |
3,7 |
355 |
| GI 120-5,5-5 |
215 |
13 |
7,6 |
3 |
1470 |
5,5 |
4,7 |
365 |
| GI 12.14-7,5-5 |
300 |
18 |
10,6 |
4 |
1470 |
7,5 |
6,5 |
375 |
| GI 15.1-7,5-5 |
340 |
20,4 |
12 |
4 |
1050 |
7,5 |
6,9 |
450 |
| GI 15.1-11-5 |
420 |
25,2 |
15 |
4 |
1320 |
11 |
9,6 |
460 |
| GI 150-11-5 |
500 |
30 |
18 |
4 |
1230 |
11 |
10,2 |
460 |
| GI 180-15-5 |
610 |
36,6 |
21 |
4 |
1320 |
15 |
12 |
480 |
|
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
| Model |
F.A.D. * |
Number of stages |
Speed |
Motor power |
Net Weight |
| [l/min] |
[rpm] |
[kW] |
[app. kg] |
| Technical Data VERTICUS Range |
| GIB12.2-5,5-5 |
6 |
2 |
1230 |
55 |
3,3 |
| 8 |
4,0 |
| 10 |
4,6 |
| 12 |
5,3 |
| GIB15.3-11-5 |
8 |
2 |
1140 |
11 |
6,6 |
| 9 |
7,1 |
| 10 |
7,7 |
| 11 |
8,2 |
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
| Model |
Free air delivery * |
Number of stages |
Speed |
Motor power |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
| Technical Data GI Range (Horizontal version) |
| GI 22.0-15 |
650 |
39 |
23 |
4 |
980 |
15 |
| GI 22.0-18,5 |
800 |
48 |
28 |
4 |
1180 |
18,5 |
| GI 22.0-22 |
930 |
56 |
33 |
4 |
1320 |
22 |
| GI 23.0-30 |
1300 |
78 |
46 |
4 |
1200 |
30 |
| GI 23.0-37 |
1480 |
89 |
52 |
4 |
1400 |
37 |
| GI 25.0-45 |
1900 |
114 |
67 |
4 |
1180 |
45 |
| GI 28.0-55 |
2500 |
150 |
88 |
4 |
830 |
55 |
| GI 28.0-75 |
3500 |
210 |
125 |
4 |
1180 |
75 |
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
 |
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS |
| |
• |
Oil lubrication (high pressure oil pump) |
| |
• |
Micronic intake filter |
| |
• |
Air-cooled inter and after coolers for all compressor stages |
| |
• |
Intermediate and final separators for oil and water condensate |
| |
• |
Safety valve after each compressor stage, final pressure safety valve with TÜV approval |
| |
• |
Pressure maintaining valve after last compressor stage |
 |
Automatic condensate drain |
| |
• |
Automatically drains oil and water in the intermediate and final separator while the unit operates |
 |
Electric control unit |
| |
• |
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters |
 |
Frame, housing |
| |
• |
MINI-VERTICUS III: Sound absorbing housing ensures quiet running, anti-vibration mounts for foundationless installation |
| |
• |
VERTICUS and large industrial series: Open frame with anti-vibration mounts for foundationless installation |
High Pressure Gas Compressors for Inert Gases (Nitrogen), GI Range 350-500 bar
GI-Series 350-500 bar
| Model |
F.A.D. * |
Number of stages |
Speed |
Motor power |
Power consumption |
Net Weight |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
[kW] |
[app. kg] |
| Technical Data VERTICUS Range |
| GI 15.11-7,5-5 |
310 |
18,6 |
11 |
4 |
960 |
7,5 |
7 |
440 |
| GI 15.11-11-5 |
420 |
25,2 |
15 |
4 |
1320 |
11 |
10,4 |
450 |
| GI 18.1-15-5 |
550 |
33,0 |
19,5 |
5 |
1320 |
15 |
12,4 |
480 |
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
| Model |
Free air delivery * |
Number of stages |
Speed |
Motor power |
| [l/min] |
[m³/h] |
[cfm] |
[rpm] |
[kW] |
| Technical Data GI Range (Horizontal version) |
| GI 25.9-45 |
1900 |
114 |
67 |
5 |
1180 |
45 |
| GI 25.18-55 |
2300 |
138 |
80 |
5 |
1100 |
55 |
 |
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS |
| |
• |
Oil lubrication (high pressure oil pump) |
| |
• |
Micronic intake filter |
| |
• |
Air-cooled inter and after coolers for all compressor stages |
| |
• |
Intermediate and final separators for oil and water condensate |
| |
• |
Safety valve after each compressor stage, final pressure safety valve with TÜV approval |
| |
• |
Pressure maintaining valve after last compressor stage |
 |
Automatic condensate drain |
| |
• |
Automatically drains oil and water in the intermediate and final separator, while the unit operates |
 |
Electric control unit |
| |
• |
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters |
 |
Frame, housing |
| |
• |
Open frame with anti-vibration mounts for foundationless installation |
|
|