BAUER KOMPRESSOREN builds high pressure systems that employ leading-edge technology and satisfy top-of-the range expectations in design and quality. Our longstanding practical experience know-how design, manufacture and installation make us a competent and reliable supplier of your high pressure compressor system, whatever your specific requirements may be. Depending on pressure and required delivery, BAUER supplies three, four or five stage high pressure gas compressors. This section of our homepage will introduce our product range for gas applications, such as noble gases (such as argon or helium), inert gases (nitrogen, for example) and compressed natural gases (CNG) or methane. Gas Compression
Our Industrial Systems According to Your Requirements!
Depending on pressure and required air delivery, BAUER KOMPRESSOREN supplies three, four or five stage high pressure gas compressors.
This section of our homepage will introduce our product range for gas applications (90 - 500 bar / 1300 - 7000 psig), such as noble gases (such as argon or helium), inert gases (nitrogen, for example) and compressed natural gases (CNG) or methane. High Pressure Gas Compressors for Noble Gases (Argon, Helium), G Range 90-220 bar
G-Series 90-220 bar
Model
F.A.D. *
Number of stages
Speed
Motor power
Power consumption
Net Weight
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
[kW]
[app. kg]
Technical Data VERTICUS Range
G 100-3-5
85
5,1
3
3
900
3
2
535
G 120-4-5
130
7,8
4,6
3
900
4
2,5
540
G 120-5,5-5
175
10,5
6,2
3
1250
5,5
3,6
555
G 15.1-7,5-5
300
18,0
10,6
4
880
7,5
5,5
620
G 15.1-11-5
400
24,0
14
4
1230
11
8,1
650
G 18.1-15-5
560
33,6
20
5
1320
15
11,6
670
* measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
Model
Free air delivery *
Number of stages
Speed
Motor power
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
Technical Data G Range (Horizontal version)
G 22.0-15
610
37
22
4
990
15
G 22.0-18,5
730
44
26
4
1180
18,5
G 23.1-22
810
49
29
4
990
22
G 23.1-30
1030
62
36
4
1250
30
G 25.9-45
1650
100
58
4
1180
45
Standard Scope of Supply
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
•
Oil lubrication (high pressure oil pump)
•
Micronic intake filter
•
Air-cooled inter and after coolers for all compressor stages
•
Intermediate and final separators for oil and water condensate
•
Safety valve after each compressor stage, final pressure safety valve with TÜV approval
•
Pressure maintaining valve after last compressor stage
Automatic condensate drain
•
Automatically drains oil and water in the intermediate and final separator while the unit operates
Electric control unit
•
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
Frame, housing
•
Open frame with anti-vibration buffers for foundationless installation
High Pressure Gas Compressors for Noble Gases (Argon, Helium), G Range 220-350 bar G-Series 220-350 bar
Model
F.A.D. *
Number of stages
Speed
Motor power
Power consumption
Net Weight
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
[kW]
[app. kg]
Technical Data VERTICUS Range
G 15.1-7,5-5
300
18
10,6
4
880
7,5
5,9
670
G 15.1-11-5
400
24
14
4
1230
11
8,6
670
G 18.1-15-5
550
33
19
5
1320
15
12
670
* measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
Model
Free air delivery *
Number of stages
Speed
Motor power
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
Technical Data G Range (Horizontal version)
G 25.9-45
1650
100
58
4
1180
45
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
•
Oil lubrication (high pressure oil pump)
•
Micronic intake filter
•
Air-cooled inter and after coolers for all compressor stages
•
Intermediate and final separators for oil and water condensate
•
Safety valve after each compressor stage, final pressure safety valve with TÜV approval
•
Pressure maintaining valve after last compressor stage
Automatic condensate drain
•
Automatically drains oil and water in the intermediate and final separator while the unit operates
Electric control unit
•
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
Frame, housing
•
Open frame with anti-vibration buffers for foundationless installation
High Pressure Gas Compressors for Inert Gases (Nitrogen), GI Range 90-350 bar
GI-Series 90-350 bar
Model
F.A.D. *
Number of stages
Speed
Motor power
Power consumption
Net Weight
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
[kW]
[app. kg]
Technical Data MINI-VERTICUS III Range
MV-GI 100-3-3
85
5
3
3
900
3
2,2
265
MV-GI 100-4-3
125
7,5
4,4
3
1270
4
3,1
265
MV-GI 120-4-3
170
10
6
3
1200
4
3,7
270
MV-GI 120-5,5-3
215
13
7,6
3
1470
5,5
4,7
270
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
Model
F.A.D. *
Number of stages
Speed
Motor power
Power consumption
Net Weight
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
[kW]
[app. kg]
Technical Data VERTICUS Range
GI 100-3-5
85
5,1
3
3
900
3
2,2
345
GI 100-4-5
125
7,5
4,4
3
1270
4
3,3
350
GI 120-4-5
170
10,2
6
3
1200
4
3,7
355
GI 120-5,5-5
215
13
7,6
3
1470
5,5
4,7
365
GI 12.14-7,5-5
300
18
10,6
4
1470
7,5
6,5
375
GI 15.1-7,5-5
340
20,4
12
4
1050
7,5
6,9
450
GI 15.1-11-5
420
25,2
15
4
1320
11
9,6
460
GI 150-11-5
500
30
18
4
1230
11
10,2
460
GI 180-15-5
610
36,6
21
4
1320
15
12
480
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
Model
F.A.D. *
Number of stages
Speed
Motor power
Net Weight
[l/min]
[rpm]
[kW]
[app. kg]
Technical Data VERTICUS Range
GIB12.2-5,5-5
6
2
1230
55
3,3
8
4,0
10
4,6
12
5,3
GIB15.3-11-5
8
2
1140
11
6,6
9
7,1
10
7,7
11
8,2
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
Model
Free air delivery *
Number of stages
Speed
Motor power
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
Technical Data GI Range (Horizontal version)
GI 22.0-15
650
39
23
4
980
15
GI 22.0-18,5
800
48
28
4
1180
18,5
GI 22.0-22
930
56
33
4
1320
22
GI 23.0-30
1300
78
46
4
1200
30
GI 23.0-37
1480
89
52
4
1400
37
GI 25.0-45
1900
114
67
4
1180
45
GI 28.0-55
2500
150
88
4
830
55
GI 28.0-75
3500
210
125
4
1180
75
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
•
Oil lubrication (high pressure oil pump)
•
Micronic intake filter
•
Air-cooled inter and after coolers for all compressor stages
•
Intermediate and final separators for oil and water condensate
•
Safety valve after each compressor stage, final pressure safety valve with TÜV approval
•
Pressure maintaining valve after last compressor stage
Automatic condensate drain
•
Automatically drains oil and water in the intermediate and final separator while the unit operates
Electric control unit
•
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
VERTICUS and large industrial series: Open frame with anti-vibration mounts for foundationless installation
High Pressure Gas Compressors for Inert Gases (Nitrogen), GI Range 350-500 bar
GI-Series 350-500 bar
Model
F.A.D. *
Number of stages
Speed
Motor power
Power consumption
Net Weight
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
[kW]
[app. kg]
Technical Data VERTICUS Range
GI 15.11-7,5-5
310
18,6
11
4
960
7,5
7
440
GI 15.11-11-5
420
25,2
15
4
1320
11
10,4
450
GI 18.1-15-5
550
33,0
19,5
5
1320
15
12,4
480
measured with flow meter at 0,8 factor of final pressure (±5%)
power consumption at final pressure 350 bar / 5000 psig
Model
Free air delivery *
Number of stages
Speed
Motor power
[l/min]
[m³/h]
[cfm]
[rpm]
[kW]
Technical Data GI Range (Horizontal version)
GI 25.9-45
1900
114
67
5
1180
45
GI 25.18-55
2300
138
80
5
1100
55
Compressor Unit» Details of the Large Industrial Series (horizontal version) or VERTICUS
•
Oil lubrication (high pressure oil pump)
•
Micronic intake filter
•
Air-cooled inter and after coolers for all compressor stages
•
Intermediate and final separators for oil and water condensate
•
Safety valve after each compressor stage, final pressure safety valve with TÜV approval
•
Pressure maintaining valve after last compressor stage
Automatic condensate drain
•
Automatically drains oil and water in the intermediate and final separator, while the unit operates
Electric control unit
•
Compressor control (consisting of B-CONTROL and possibly extensions) for VERTICUS and large industrial series. The unit monitors relevant compressor parameters
Frame, housing
•
Open frame with anti-vibration mounts for foundationless installation